VOLTFORMER · Electrical Analysis
Electrical Analysis
Build an electrical model you can draw, inspect and hand over. Voltformer brings single line diagrams, equipment data, supported engineering studies and project revisions into one browser workspace.
Open project workspaceSign in, create or open a project, then open Electrical Analysis. Your project documents are private.
Engineering capabilities and model limits
Status describes the implemented model, not project approval. Reference-tested calculations have regression benchmarks within their stated scope; they are not a certification or a claim of ETAP or PowerFactory parity. Review input provenance, readiness, convergence and warnings for every study.
- Network modeling and deliverablesImplemented
- Create connected single-line diagrams, link catalog equipment to supported symbols, save project revisions and prepare BOM, cable schedules, engineering reports and SVG, PNG, PDF, DXF or JSON exports.
- AC and DC power flowReference-tested
- Balanced AC Newton-Raphson load flow covers slack voltage, PV generators with reactive limits, ZIP loads, cable charging, transformer core, taps and reactive controls. Declare each value; absent data keep constant P/Q and unity reactive output. Separate ABC and DC studies require explicit source-backed matrices or resistance models.
- Fault analysisReference-tested
- IEC 60909-0:2016 Ik″, ip, Ib, idc and Ith, ANSI/IEEE C37.010 and C37.13 E/X duty, and configured sequence-network faults use declared impedances and grounding. Conformance with IEC 60909-0:2026 is not verified. Missing zero-sequence paths, motor or converter contributions are not inferred.
- Protection coordinationLimited model
- Relay curves, branch fault contributions, sequence of operation, tolerance sweeps and IEEE 1584-2018 arc flash with relay clearing time support coordination review. Complete selectivity and manufacturer-approved relay settings require a separate project review.
- Motor starting, harmonics and dynamicsLimited model
- Motor starting, harmonic impedance and injection with IEEE 519-2022 limit checks, supported RMS dynamics, P-V loadability, time-series load flow and IEEE 80 uniform-soil grid safety have explicit input and model limits. They do not establish OEM converter response, electromagnetic transients or project compliance.
- Network, planning and transient studiesLimited model
- DC and AC optimal power flow, continuation and Q-V stability, state estimation, N-1 and N-2 outages, hosting capacity, capacitor placement, reliability indices, IEC 60287 cable rating, IEEE 485 battery sizing, small-signal modes and a nodal electromagnetic transient solver run on declared data, on a drawing or on imported MATPOWER, PSS/E RAW v33 or CIM cases. They do not establish OEM converter response or project compliance.
- Broader simulation roadmapPlanned
- Demand forecasting, battery state models, OEM converter and relay model libraries, real-time SCADA links, CGMES conformity and third-party quality certification remain planned. Renewable templates and equipment symbols do not imply validated interconnection compliance.
From one-line drawing to project deliverables
- Place electrical symbols, connect terminals and organize busbars, equipment and annotations.
- Link compatible catalog equipment to diagram elements and inspect the resulting technical properties.
- Run supported load-flow, fault and other study workflows; review input requirements, convergence and model limits.
- Save revisions and export diagrams or study deliverables. Available workflows include SVG, PNG, PDF, DXF, JSON and engineering reports.
Create your first single line diagram
- Create a project and select a blank diagram or a starter template (distribution substations, utility-scale solar PV + BESS, or rooftop solar + battery storage). Review and replace the example ratings for your project.
- Enter equipment ratings, voltage levels, source data and connection states. Check actual terminal connections, not just crossing lines.
- Validate the model, inspect warnings and run the study appropriate to the question. Resolve missing data before relying on results.
- Save a revision and export the drawing with the assumptions and study results needed by the reviewer.
Considering an ETAP alternative?
Voltformer is an option to evaluate for browser-based SLD drawing, catalog-linked project preparation and supported study workflows. ETAP documents a broader integrated modeling and operational ecosystem. Select by your required calculation methods, device models, exchange formats and acceptance criteria; this page does not claim full ETAP equivalence or native ETAP project import.
ETAP vs PowerFactory vs Voltformer: Capability and Verification EvidenceEngineering scope and review
A drawing is not an approved study. Results depend on topology, equipment data, solver assumptions and the selected model. Review readiness, unavailable results and warnings. Validate safety-critical deliverables against your project requirements and an accepted reference method.

Electrical Analysis for connected agents
Inspect the public getSldCapabilities tool and API reference. Reading or changing member diagrams requires an authenticated account and the appropriate project scopes. Version checks protect saves; a successful API response is not engineering approval.
getSldCapabilities · MCP / REST APIPractical SLD guides
ETAP vs PowerFactory vs Voltformer: Capability and Verification Evidence
Evaluate Voltformer Electrical Analysis for connected single-line models, supported studies and engineering handover, using explicit capability limits and a reproducible acceptance checklist.
How to Create an Electrical Single Line Diagram Online
Build a connected model in Voltformer Electrical Analysis, document source-backed inputs, check three-phase power and current, and hand over a traceable engineering revision.
Single Line Diagram vs Load-Flow Model: Validation Before Analysis
Validate an Electrical Analysis model before load flow: check connectivity, input provenance, power balance, study scope and reproducibility without confusing convergence with design approval.
Load Flow Analysis Explained: AC, DC and a Reproducible Two-Bus Example
Understand AC load-flow equations, distinguish two DC models, and reproduce a two-bus solution with explicit units, power balance and engineering limits.
IEC 60909 Short-Circuit Calculations: Worked Check, Edition and Model Limits
Reproduce a 1000 kVA transformer screening check, derive R/X from declared losses, and distinguish current duties, IEC editions and unverified model assumptions.
Questions before you start
Is this an online single line diagram editor?
Yes. The editor runs in the browser inside a signed-in Voltformer project workspace. This public page explains the workflow without exposing member documents.
Can I transfer an ETAP project directly?
Native ETAP project import is not advertised. Confirm the supported format and reconstruct or exchange only the information the target model actually supports.
Does a DXF or PDF export preserve the calculation model?
Treat drawing exports as deliverables. Retain the structured project data and study package separately; a visual export alone does not establish lossless model exchange.