# GE Vernova SVC Coupling Transformer 100 MVA 230/15.75 kV

> GE Vernova SVC coupling transformer family for harmonic-duty voltage support and reactive-power compensation.

> SKU: VF-GEV-SVC-100M-230 | Brand: GE Vernova (General Electric) | Category: Power & Energy Equipment / Transformers / Special Industrial & Process Transformers / STATCOM, SVG & Power-Quality Coupling Transformers

**Voltformer canonical:** https://voltformer.com/product/ge-vernova-svc-coupling-transformer-100-mva-230-kv - markdown version: https://voltformer.com/product/ge-vernova-svc-coupling-transformer-100-mva-230-kv.md

## Overview

GE Vernova SVC Coupling Transformer 100 MVA 230/15.75 kV is intended for Wind & Solar Grid-Code Compliant STATCOM Reactive Power Compensation. Configured electrical data: 100 MVA, 230/15.75 kV primary/secondary voltage, 50 Hz, 3-phase, vector group YNd11 and short-circuit impedance 12%. Construction: Copper (Cu-Cu); cooling: ONAN/ONAF; loss class: STATCOM / SVG High dv/dt Grade. These values support preliminary engineering selection; verify insulation levels, thermal limits, short-circuit duty, installation conditions and applicable standards against the manufacturer datasheet and the site study.

- **Application:** Wind & Solar Grid-Code Compliant STATCOM Reactive Power Compensation
- **Target industries:** Utility-Scale Solar & Wind Farms, Grid Reactive Power Compensation Substations, Steel Mills & Metallurgical Works
- **Brand:** [GE Vernova (General Electric)](https://voltformer.com/brand/ge-vernova.md) - GE Vernova Grid Solutions provides high-performance protection, control, and automation solutions including the renowned Multilin 8 Series and MiCOM Agile product lines.
- **Category:** [Power & Energy Equipment](https://voltformer.com/catalog.md) / **Transformers** / [Special Industrial & Process Transformers](https://voltformer.com/category/special-industrial-process-transformers.md): Arc furnace (EAF), green hydrogen electrolyser, rectifier, traction and mining Ex-proof transformers. / [STATCOM, SVG & Power-Quality Coupling Transformers](https://voltformer.com/category/special-industrial-process-transformers/statcom-svg-power-quality-coupling-transformers.md)

## Technical Specifications

| Property | Value |
|---|---|
| Rated power | 100 MVA |
| Primary / secondary voltage | 230 kV / 15.75 kV (±2 x 2.5%) |
| Frequency / phases | 50 Hz / 3-phase - YNd11 |
| Short-circuit impedance (Uk) | 12% |
| No-load loss P0 | 60.00 kW |
| Load loss Pk | 471.4 kW |
| Calculated efficiency (power factor = 1) | 99.4714% at 100% load; 99.6455% at 50% load |
| Loss class | STATCOM / SVG High dv/dt Grade |
| Windings | Copper (Cu-Cu) - cooling: ONAN/ONAF - insulation: Class A |
| Temperature rise | 65 K - sound pressure: 62 dB(A) |
| Mass and dimensions | 52000 kg - 5200×3300×4600 mm |
| Enclosure | IP55 - wheel gauge: 1600 mm |
| LI / AC withstand | 575 kV peak / 276 kV rms - partial discharge: 5 pC |
| Environment | -25°C / +40°C; altitude ≤ 1000 m |
| Core steel | CRGO Laser-Treated Grain-Oriented Silicon Steel (23ZDMH85 / Baosteel B23R085) |
| Bushings / terminals | Direct Copper Busbar Terminals (Busbar Integrated / IP00-IP31) |

## Standards

- IEC 60076
- IEC 61378-1
- IEEE C57.18.10

## Accessories

**Included:** SVC coupling interface, Harmonic-duty monitoring, Pressure relief device
**Optional:** Main reactor interface, Online DGA, Bushing monitoring

## Official sources

- https://www.gevernova.com/electrification/systems/flexible-ac-transmission-systems-facts/static-var-compensator-solutions
- https://www.gevernova.com/electrification/equipment/transformers/power-transformers
- https://www.gevernova.com/electrification/automation/protection-control-metering/

- **Source scope:** manufacturer-family
- **Last reviewed:** 2026-09-13

Manufacturer family/application source. GE Vernova describes SVC transformers that connect medium-voltage equipment to the high-voltage transmission grid and publishes SVC system designs from industrial to utility ratings. The 100 MVA, 230/15.75 kV envelope is project configured. Exact order code, guaranteed losses, dimensions, insulation level, cooling stage, winding material and project options must be confirmed with the OEM before procurement or an SLD study.

## Pricing & Logistics

- Pricing type: RFQ (Project Engineering) - Indicative range: $360,000 – $430,000 USD
- Delivery time: 2–8 weeks (may vary depending on technical configuration, factory capacity and destination) - Warranty: 36 months
- Compliance candidates: IEC 60076, IEC 61378-1, IEEE C57.18.10. Verify applicability and conformity against the exact offered model and project jurisdiction.