### 1. Secondary Distribution Ring Main Unit (RMU) Functions

Ring Main Units provide compact medium-voltage protection and switching in underground distribution loops (ring networks) for compact transformer kiosks and commercial facilities.

### 2. Standard Functional Module Configurations

| RMU Configuration Code | Composition of Functional Blocks | Typical Application |
|---|---|---|
| **CCF** | 2 Cable Switches (C) + 1 Fuse-Switch (F) | Compact kiosks up to $1250\text{ kVA}$ |
| **CCV** | 2 Cable Switches (C) + 1 Vacuum Circuit Breaker (V) | Substation transformers $> 1250\text{ kVA}$ |
| **CCCF / CCCV** | 3 Cable Ring Switches + 1 Transformer Feeder | Ring branch nodes and meshed grids |
| **CCCC** | 4 Cable Load-Break Switches | Sectionalizing and bus-tie loop stations |

### 3. Smart Grid Automation & Telecontrol Protocols

To enable automated Fault Location, Isolation, and Service Restoration (FLISR):
- **Directional Fault Passage Indicators (FPI):** Detect phase-to-phase and earth fault current paths.
- **24 VDC Motorized Mechanisms:** Actuate switches in $< 3\text{ seconds}$ via SCADA commands.
- **Protocol Support:** **IEC 60870-5-104** (Ethernet TCP/IP) and **DNP3 Secure**.

### 4. Hermetic Sealed Tank Reliability

Primary live busbars, switches, and disconnectors are enclosed inside a laser-welded stainless steel tank with **IP65 ingress protection** and $>30$-year gas tightness per **IEC 62271-200**.

*Reference: IEC 62271-200:2021; IEC 60870-5-104; IEEE Std C37.20.3.*

---

## Related Equipment & Catalog Cross-References

- [Transformers Catalog](https://voltformer.com/catalog.md): Browse medium and high voltage power transformers.
- [Medium Voltage Switchgear](https://voltformer.com/catalog.md): Air-insulated (AIS) and gas-insulated (GIS) switchgear panels.
- [Protection & Control Relays](https://voltformer.com/catalog.md): ANSI 87T differential, overcurrent and feeder protection relays.
- [Machine-Readable API Catalog](https://voltformer.com/agent-catalog.json): Autonomous agent catalog data.