{
  "language": "en",
  "interfaceLanguage": "en",
  "url": "https://voltformer.com/articles/how-to-create-electrical-single-line-diagram-online",
  "id": "sld-guide-2",
  "slug": "how-to-create-electrical-single-line-diagram-online",
  "title": "How to Create an Electrical Single Line Diagram Online",
  "summary": "Build a connected model in Voltformer Electrical Analysis, document source-backed inputs, check three-phase power and current, and hand over a traceable engineering revision.",
  "readTime": "5 min read",
  "date": "2026-09-27",
  "author": "Voltformer",
  "category": "Single Line Diagrams",
  "tags": [
    "SLD",
    "Single Line Diagram",
    "Engineering"
  ],
  "contentMarkdown": "Electrical Analysis is Voltformer’s engineering workspace. Its single-line diagram editor connects the drawing, equipment inputs and supported studies; it is one part of the workflow. This guide separates model preparation, numerical checks and engineering acceptance.\n\n### 1. Gather the model inputs\n\nDefine the purpose of the diagram: concept design, equipment procurement or a specific engineering study. Gather supply voltage and frequency, source fault data, transformer ratings and impedance, cable lengths and impedance, loads, protection settings and normal switch positions. Record where each value came from. Unknown values should remain an explicit data request rather than a plausible-looking assumption.\n\n### 2. Build a small connected network\n\nOpen a Voltformer project and its Electrical Analysis workspace. Begin with a source, transformer, receiving bus and one outgoing feeder. Connect the intended terminals, enter ratings and inspect the electrical properties. Expand the model only after this small network behaves as expected. Crossing lines are not proof of connectivity.\n\nUse a consistent voltage basis. For a balanced three-phase example, 1 MVA at 11 kV corresponds to approximately 52.5 A using I = S / (√3 × U), with U as line-to-line voltage. This checks a unit conversion; it does not size a cable or establish equipment fault duty.\n\nName equipment and buses consistently so a reviewer can trace the diagram to the equipment list. Check open ties, isolated loads and transformer sides before running a study.\n\n### 3. Review and hand over\n\nRun model validation and inspect warnings before analysis. Select the study for the engineering question, check convergence and unavailable outputs, and retain assumptions. Change one input at a time when investigating a surprising result.\n\nSave a named revision before issuing a drawing. Export the visual deliverable and retain structured project data plus relevant study reports. The recipient should be able to identify the revision, operating case, equipment data and unresolved items. A PDF is a communication artifact; it does not by itself prove that the model is complete or approved.\n\n### 4. Keep an input register alongside the drawing\n\n| Input | Evidence and interpretation |\n|---|---|\n| Source | Utility voltage, frequency, fault level and impedance basis; identify missing data. |\n| Transformer | Rated power, winding voltages, connection, impedance, tap and relevant test-report conditions. |\n| Branch | Length, conductor arrangement, impedance units and the basis of resistance values. |\n| Load | Active/reactive demand or power factor; distinguish operating demand from equipment nameplate. |\n| Switching | Normal/open state, ties, energized islands and the intended source for each case. |\n| Protection | CT ratios, current bases, device settings and clearing-time assumptions where required. |\n\n### 5. Check one transparent three-phase example\n\nAssume a balanced sinusoidal load of **800 kW at 0.8 lagging power factor**. These are teaching inputs, not a catalog specification or a reported solver run. Apparent power is `S = P / pf = 1000 kVA`; reactive power is `Q = √(S² − P²) = 600 kvar`. With line-to-line voltage `U_LL`, line current is `I = S / (√3 × U_LL)`.\n\nUsing VA and V gives `1,000,000 / (√3 × 11,000) = 52.49 A` at 11 kV, or `1,000,000 / (√3 × 400) = 1443.38 A` at 400 V. The two currents describe the same assumed apparent power at different voltage levels; they are not a complete transformer solution. Losses, voltage drop, imbalance and harmonics are excluded. Do not use this current check as cable ampacity, breaker-duty or transformer thermal approval.\n\n### 6. Issue a revision that another engineer can reproduce\n\nKeep the source documents, input units, operating case, selected study, settings and unresolved data requests with the exported drawing. Compare catalog values with the intended equipment variant and its documentation; a family-level description is not a verified test value. When a supplier revises impedance or the utility revises fault data, retain the previous case and identify the changed input before recalculating. A later data revision should not silently rewrite the engineering basis of an earlier report.\n\n### Engineering references and next steps\n\n[Voltformer Electrical Analysis](/single-line-diagram-editor) · [ETAP Alternative for Single Line Diagrams: A Practical Selection Guide](/articles/etap-alternative-single-line-diagram-editor) · [Single Line Diagram vs Load-Flow Model: Validation Before Analysis](/articles/single-line-diagram-load-flow-model-validation) · [Transformer FAT and Site Commissioning: IEC 60076 Test Plan](/articles/transformer-factory-acceptance-tests-iec-60076) · [Instrument Transformers: CT and VT Selection for Metering and Protection](/articles/instrument-transformers-ct-vt-metering-protection-selection) · [API](/agent-api#tool-getSldCapabilities) · [DIgSILENT — Load Flow Analysis](https://www.digsilent.de/en/load-flow-analysis.html)\n\nEditorial review: 23 October 2026. Existing publication date and permanent URL preserved; capability scope checked against the current Electrical Analysis description.",
  "contentLanguage": "en",
  "sources": [
    {
      "name": "Voltformer — Electrical Analysis: implemented capabilities and model limits",
      "url": "https://voltformer.com/single-line-diagram-editor.md"
    },
    {
      "name": "DIgSILENT — Load Flow Analysis, official product documentation",
      "url": "https://www.digsilent.de/en/load-flow-analysis.html"
    }
  ]
}
